Network Interface Board
The Network Interface Board allows up to 99 FireFinder Marine panels (nodes) to be connected in a high integrity redundant network configuration. The network is capable of withstanding an open or short circuit fault without the loss of communication to any nodes.
The network operates as a peer-to-peer network, with all device state changes shared over the network. Each node can be configured as to which state changes are displayed. This configuration is specified in terms of nodes, loops, or groups.
- Supports Redundant Network with Isolated Network In and Out Ports.
- Up to 99 Network Nodes.
- 115200 Baud Rate.
- 1.2km between Nodes.
- Uses industry-standard RS485.
- Diagnostic LEDs.
Operating Voltage | 27 V dc |
Quiescent Current | 41 mA |
Max Nodes | 99 |
Protocol | RS485 |
Recommended Cable | 2 Core, Screened Fire Resistant |
Cable Length Node to Node | 1.2 km |
Temperature | -5ºC to 40ºC |
4210-0006 | 2 Wire Network Card |